Advertisement

News Headlines

Sun. Aug 23rd 2009
Truck For Sale

Station 24 Seneca is looking for a buyer for our old second out engine. 1000gal tank, 1500 pump. 5 man cab with 2 open jump s...

Read more »


Mon. Jul 13th 2009
STATION 24 SENECA WILL BE HOSTING AN OPEN HOUSE OCT 10TH AND A 60TH ANNIVERSARY

ON OCTOBER 10TH 2009 THE SENECA FIRE DEPARTMENT WILL BE HOSTING AN OPEN HOUSE AND 60TH ANNIVERSARY DINNER. THE OPEN HOUSE IS ...

Read more »


Mon. Jul 13th 2009
SENECA ROLLS IN NEW TRUCK!!!!!!!!!!

STATION 24 SENECA GETS THE ARRIVAL OF NEW PUMPER TANKER AN HME WITH 2500 GAL TANK AND 1500 PUMP WITH 6 MAN CAB.

Read more »

Apparatus Gallery
Newsletter Subscription

Stay up to date!
Subscribe to our Newsletter.


Enter Your Email Address:



Contact Information

Seneca Vol. Fire Dept
3494 State Route 257
Seneca, PA  16346

Non-Emergency:
814-676-1305

Emergency:
911

Fax:
814-677-2199

Contact Us
Driving Directions
Map

Member Login

Username:


Password:




Links

Perry Hi-Way Hose Company


Emlenton Volunteer Fire Department

Mutual Aid Department Station 55 Station 55 is dispatched for every structure fire in Cranberry Twp they are on first alarm ...


President Township Volunteer Fire Department

Mutual Aid Department Station 18




 Fire Glossary
 Print this page

Search:

Click a letter to view all entries that begin with that letter:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Page: | 1 | 2 |

Halligan tool (or "Hooligan")
Forcible entry tool with a pointed pick and a wedge at right angles on one end of a shaft and a fork or cat's paw at the opposite end. Used in combination with maul or flat-headed axe for forcing padlocks, doors and windows. Based upon original design by Hugh Halligan of FDNY. Forms the irons" when nested with a flathead axe. Various shaft lengths provide mechanical advantage. Derived from the claw tool (fork and hook).


Halon
Chemical gas fire extinguishing or liquid agent for diminishing the combustion reaction rate by acting as a thermal ballast; used mainly in closed computer rooms, aircraft, and other high-value installations where corrosive chemicals or water extinguishers are judged inappropriate. Effective at low concentrations (5%) as compared with CO2 (34%). Being phased out with suitable replacements in most applications, with very restricted exemptions, due to international environmental concerns with this and other CFCs.


Halyard
Utility rope for raising or lowering moving parts of extension ladder.


Hand crew
A number of individuals that have been organized and trained and are supervised principally for operational assignments on an incident. In the United States, a typical hand crew is 20 in number.


Hard Line
A smaller hose about one inch in diameter used by firefighters to clean apparatus.


Hard suction hose
Non-collapsible sections of hose, usually 10 feet long, used when drafting.


Hazard
A source of danger of personal injury or property damage; fire hazard refers to conditions that may result in fire or explosion, or may increase spread of an accidental fire, or prevent escape from fire. Under worker safety and health regulations, employers have a general duty to provide a workplace free of hazards. See also fire prevention, and HAZMAT.


HAZMAT
Hazardous materials, including solids, liquids, or gasses that may cause injury, death, or damage if released or triggered.


Head of a fire
The most rapidly spreading portion of a fire's perimeter, usually to the leeward or up slope.


Heavy fuels
Fuels of large diameter such as snags, logs, large limb wood, which ignite and are consumed more slowly than flash fuels.


Helispot
A natural or improved takeoff and landing area intended for temporary or occasional helicopter use, typically in remote areas without other access.


Helitack
A fire crew trained to use helicopters for initial attack, and to support large fires through bucket drops and the movement of personnel, equipment and supplies.


Higbee cut (Higby cut'
A tapered thread termination in a firehose coupling for avoiding cross-threading, the location of which is indicated by a notch cut into a single lug on a hose coupling. If the notches are aligned on mating couplings, the Higbee cuts are aligned and the threads will immediately engage when the swivel fitting is turned.


High Pressure Fog (HPF)
A suppression technique consisting of finely atomized water droplets at several hundred pounds per square inch of pressure. By far, one of the most efficient suppression techniques available. Advantages include a *very* high conversion rate, unmatched atmospheric cooling and control of thermal layers, very little wasted water (and consequent water damage), and the ease of managing a small diameter booster line (defined above) during application. Disadvantages are lack of distance, lack of penetration into various materials, and high risk of burns to the attack crew. HPF is quite popular in Europe, but was discarded in the U.S. due to different building construction and the resulting increase in disadvantages.


High-pressure system
A supplemental pump system used to pressurize the water supply, sometimes used during a large fire, or whenever more than one hydrant is being used.


High-rise building
Any building taller than three or four stories, depending upon local usage, requiring firefighters to climb stairs or aerial ladders for access to upper floors.


High-rise pack
A shoulder load of hose with a nozzle and other tools necessary to connect the hose to a standpipe.


High-rise pack
Hose bundle prepared for carrying to a standpipe in a high-rise building, usually consisting of 50 or more feet of 1 3/4-inch hose and a combination nozzle.


Hook
Forged steel hook at end of insulated pole of varying lengths; used for piercing and pulling building materials away from walls and ceilings. Similar to nautical gaff hook. Short hook with a pointed tip is a pike pole; longer hook on a San Francisco hook; two offset hooks on either side of tip is a universal hook; long p-shaped hook is a Boston rake for pulling plaster and lath; short hook with claw on opposite side of tip is either a gypsum hook or the narrower ceiling hook; pike pole with a short handle is a somewhat useless closet hook.


Hose
Flexible conduit for moving liquids under pressure; made of various materials including cotton, rubber or plastic (such as PVC); construction may be braided, woven, wrapped or extruded, often in layers (liner and jacket); hose construction and size differs according to its intended use (e.g., hard suction, attack, forestry, booster); typically stocked in standard lengths and coupled together with standardized fittings. See hose coupling.





GUESTBOOK

PLEASE LEAVE A MESSAGE IN OUR GUESTBOOK AND LET US KNOW WHAT YOU THINK.


Recent Calls

Mon. Aug 23rd 2010
Seneca responds to MVA

Crews responded to mva with 1 pt still in the vehicle. Vehicle on its side in the ditch into a utility poll.

Read more »


Mon. Aug 23rd 2010
Seneca Responds to 2nd LZ

UPMC NW needed 2nd LZ for 2 trauma pts.

Read more »


Mon. Aug 23rd 2010
Seneca Responds to Car in the Woods

1 vehicle off the roadway into the woods.

Read more »

Upcoming Events

Every 1st Thu. 8:00pm
General Memebership Meeting


Every Mon. 7:00pm
SVFD Work Night

Picture Gallery
Search Our Site

Search:



2010 Call Volume
January  
February  
March  
April  
May  
June  
July  
August  
September  
October  
November  
December  
Total 0

View Call Volume History


YourFirstDue.com Managed web hosting for Fire/EMS



Login



Copyright © 2006-2010. YourFirstDue Inc.. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Content on this web site is supplied by Seneca Vol. Fire Dept. YourFirstDue Inc. cannot be held responsible or liable for any content, text, pictures, or any other media found on this web site. Maintained by the members and staff of Seneca Vol. Fire Dept.

This site has been
viewed 111,445 times.
Advertisement